Jumat, 12 Juni 2015

UPS RIEELLO AROS - SOFWARE AND CONNECTIVITY










PowerShield³
























Communication Software

PowerShield³ provides efficient, user-friendly UPS management using bar chart displays to show major operational information such as the input voltage, UPS load % and batteries charge %.
The software also provides detailed information on fault conditions and UPS operating characteristics. PowerShield³ has been developed with a client/server architecture that makes it flexible and easy to use, and provides multi-lingual and on-line support.


PowerNetGuard

































Supervision software

PowerNETGuard software centralises UPS management using network interface (SNMP) communications. It is ideal for Data Centre managers and medium to large sized networks. PowerNETGuard uses the RFC1628 standard Management Information Base (MIB) and ensures standardised UPS management wherever they are located.



NetMan 204

Network card

The NetMan 204 network agent allows UPS directly connected over LAN 10/100 Mb connections to be managed using the main network communication protocols (TCP /IP , HTTP HTTPS, SSH, SNMPv1, SNMPv2 and SNMPv3). It is the ideal solution for the integration of UPS over Ethernet networks with Modbus/TCP and BACnet/IP protocols. It was developed to integrate UPS into medium-sized and large networks, to provide a high level of reliability in communication between the UPS and associated management systems.


Environmental sensors






































Environmental monitoring integrated with the UPS

The Netman environmental sensors monitor and record environmental conditions as well as activities in protected areas and at the premises where the UPS is installed.
The environmental sensors allow extensive control and management of the environment around the UPS by monitoring the temperature, humidity, triggering devices such as fans or locks and communicating the values via web, SNMP and via the PowerShield³ software.


MultiCOM 301/302

















ModBUS Protocol Converter

The MultiCOM 301/302 protocol converter may be used to monitor the UPS using the MODBUS/JBUS protocol on RS485 or RS232 serial line. It will also manage a second, independent RS232 serial line that can be used to connect other devices such as the Netman 101 or a PC that uses the PowerShield³ software.


MultiCOM 351/352


















Serial link duplexer

The MultiCom 351/352 is a serial duplexer that allows two devices to be connected to a single serial port on a UPS.
It can be used where numerous serial connections and multiple polling of UPS are required, and is ideal for LAN networks with a firewall.


MultiCOM 372

















Serial / EPO port

MultiCOM 372 provides a UPS with an additional RS232 serial interface port. The card has Emergency Power Off (EPO) and Remote Shut Down (RSD) inputs with terminal connections.


MultiCOM 382



















Contacts / EPO board

MultiCOM 382 provides a set of relay contacts to provide UPS alarm and status indication.
The contacts are connected through terminal connections. Signal contacts include Emergency Power Off (EPO), Remote Shut Down (RSD), On Battery, On Bypass, Alarm and Low battery. The contacts are change over or normally open.



MultiCOM 401














Profibus Protocol converter

The MultiCOM 401 connects a Riello UPS to a Profibus DP Network. In industrial environments, the Gateway integrates UPS management and monitoring into a control system. The Gateway uses the field bus design – one of the most popular used for communicating between devices such as automation control systems and distributed I/O hardware.


Multi I/O















Protocol converter

Multi I/O has configurable input and output signal contacts to allow UPS integration with control systems.It can be used to connect two devices to a single UPS serial communication port. It can also communicate using the MODBUS/JBUS protocol on RS485 lines.

Kit for AS400 and iSeries™






















Communication Kit

Due to its single-level memory management feature, it is compulsory for any IBM AS/400 system to be UPS protected so that an orderly and controlled shutdown can be achieved. Without a UPS, any protracted mains failure or momentary loss of power will lead to a lengthy recovery period as the AS/400 reboots itself.
In addition sudden loss of electrical power can itself damage the AS/400. The RIELLO UPS AS/400 system connection kit allows the UPS to be connected to the AS/400 shutdown system to prevent this happening.


RTG 100















MODEM GPRS

The GPRS RTG 100 terminal is able to manage UPS connected directly to the GSM mobile telephone network. It was developed to integrate UPS into the
TeleNetGuard remote control system for complete control of UPS and diagnostics in the event of failure without the need for landline connections.
The RTG 100 is able to communicate constantly with UPS to provide the TeleNetguard remote control system or PowerShield³ software with a valid alternative to connection systems employing communication cables.


MultiPanel


















































Remote Monitoring Panel

MultiPanel is a remote monitoring device that can provide a detailed UPS status overview in real time. It is compatible with all Riello UPS and can display values for UPS specific input and output supplies, and battery set measurements.
MultiPanel has a high-definition graphical display and can report in 7 languages: English, Italian, German, French, Spanish, Russian and Chinese. It has 3 independent serial ports, one of which allows for UPS monitoring via the MODBUS/JBUS protocol (on either an RS485 or RS232 serial line). The others can be used with devices such as the Netman 101 Plus or a PC running PowerShield³ software.

Communication card adapter















Adapter for communication cards

This adapter allows you to use the Riello UPS communication cards via an RS232 port. Is the optimal solution for use with legacy UPS without a slot or for use with UPS equipped with only one expansion slot.